Biological Information
Background Information:
Lability to hydrolytic enzymes found in plasma and blood can be a limitation for the in vivo efficacy of a therapeutic compound. Eurofins has a high-throughput assay to determine metabolic stability in plasma and blood from various species using LCMS analysis to quantify the percent compound remaining after incubation.
Construct Details:
Endogenous
Tissue:
Plasma
Assay Information
Assay Type:
Biochemical
Assay Sub Type:
Enzymatic
Detection Method:
HPLC-MS/MS
Measured Response:
Peak Area Response
Testing Information
Substrate:
Test compound
Turnaround Time
Standard:
15 Business Days
Additional Information
Brand:
Cerep
Testing Location:
USA - St Charles, MO